The Open UniversitySkip to content
 

Fabrication of an endoneurium using engineered neural tissue within a peripheral nerve repair conduit

Georgiou, Melanie; Golding, Jon; Loughlin, Jane and Phillips, James (2013). Fabrication of an endoneurium using engineered neural tissue within a peripheral nerve repair conduit. In: Tissue Engineering and Regenerative Medicine International Society - EU Meeting, 17-20 June 2013, Istanbul, Turkey.

Full text available as:
[img]
Preview
PDF (Version of Record) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
Download (379kB) | Preview
URL: http://www.termis.org/eu2013/docs/termisEU2013_pro...
Google Scholar: Look up in Google Scholar

Abstract

Peripheral nerve injury as a result of trauma affects approximately 1 million people in Europe and America annually. The current clinical gold standard treatment for repairing long gaps is the nerve autograft, in which only ~50% of cases result in satisfactory functional recovery. Tissue-engineered cellular bridging devices for peripheral nerve repair could provide an attractive alternative to autografts. Sheets of engineered neural tissue (EngNT), which is formed from columns of Schwann cells within a 3D aligned collagen matrix, can promote directed neurite outgrowth in vitro. These sheets of EngNT can be arranged to form the ‘endoneurium’ of a peripheral nerve repair device. Two different arrangements, rod-based and sheet-based designs, were tested within a clinically approved tube, NeuraWrap™, in a 5mm gap in the rat sciatic nerve. Cross sections were stained to detect neurofilament after 4 weeks in vivo and revealed where the axons were growing in relation to the EngNT structures (this was divided into three zones for the analysis). The axon density was significantly greater in zone 1 than in zone 3 in the devices (P<0.05, oneway ANOVA). The rod-based arrangement (A) gave a higher axon density in zone 1, 3350 ± 143 axons/mm2 (mean ± SEM), compared to the sheet-based arrangement (B) (2920 ± 587 axons/mm2). The rod-based arrangement was more stable; there were no observed changes to its structure or orientation as a result of surgical handling or limb movement post-implantation. The designs are modular and can be adapted for the repair of bigger nerves by, for example, having multiple rod structures in the core of outer tubes or sheath wraps. Aligned cellular EngNT rods can form the basis of a functional conduit for peripheral nerve repair.

Item Type: Conference or Workshop Item
Copyright Holders: 2013 Not known
Academic Unit/School: Faculty of Science, Technology, Engineering and Mathematics (STEM) > Life, Health and Chemical Sciences
Faculty of Science, Technology, Engineering and Mathematics (STEM)
Interdisciplinary Research Centre: Biomedical Research Network (BRN)
Related URLs:
Item ID: 37856
Depositing User: James Phillips
Date Deposited: 02 Jul 2013 10:43
Last Modified: 31 Jan 2017 08:23
URI: http://oro.open.ac.uk/id/eprint/37856
Share this page:

Download history for this item

These details should be considered as only a guide to the number of downloads performed manually. Algorithmic methods have been applied in an attempt to remove automated downloads from the displayed statistics but no guarantee can be made as to the accuracy of the figures.

▼ Automated document suggestions from open access sources

Actions (login may be required)

Policies | Disclaimer

© The Open University   + 44 (0)870 333 4340   general-enquiries@open.ac.uk