Hall, David J.; Holland, Andrew and Smith, David R. (2009). The use of automatic scale selection to improve the spatial and spectral resolution of a scintillator-coupled EMCCD. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 604(1-2) pp. 207–210.

Full text available as:
[img]
Preview
PDF (Accepted Manuscript) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
Download (180Kb)
DOI (Digital Object Identifier) Link: http://dx.doi.org/10.1016/j.nima.2009.01.075
Google Scholar: Look up in Google Scholar

Abstract

The technology behind the Electron-Multiplying Charge Coupled Device (EMCCD) was successfully exploited by e2v technologies in the late 1990s. Since then, many uses have been found for these low light level (L3) devices including surveillance and many scientific applications. The EMCCD increases or 'multiplies' the charge signal by the phenomenon of impact ionisation (or avalanche multiplication) allowing the detection of low signal events of only a few photons. When coupled with a scintillator, this low light capability can be used to image photon flashes from individual X-ray interaction events. The combination of depth of interaction effects in the scintillator, shot noise on the signal and the multiplication noise factor lead to large variations in the profile of the detected signal from a constant energy X-ray source. This variation leads to reduced spectral performance and can have adverse effects on the centering techniques used in photon-counting imagers. The concept of scale-space is similar in many ways to the Fourier or wavelet transforms. Automatic scale selection can be implemented through the scale-space transform as a method of fitting a known profile to the observed photon flash. The process is examined here in the context of the photon-counting EMCCD detector and the results obtained in both simulated and experimental data compared. Through the analysis of the fitting process and the results achieved, the implications on imaging performance and spectral resolution are discussed.

Item Type: Journal Article
Copyright Holders: 2008 Elsevier B.V
ISSN: 0168-9002
Keywords: photon counting; scintillator; EMCCD; Geant4; scale-space; automatic scale selection
Academic Unit/Department: Science > Physical Sciences
Interdisciplinary Research Centre: Centre for Earth, Planetary, Space and Astronomical Research (CEPSAR)
Item ID: 15506
Depositing User: Karen Guyler
Date Deposited: 14 May 2009 13:55
Last Modified: 01 Dec 2013 11:35
URI: http://oro.open.ac.uk/id/eprint/15506
Share this page:

Actions (login may be required)

View Item
Report issue / request change

Policies | Disclaimer

© The Open University   + 44 (0)870 333 4340   general-enquiries@open.ac.uk