The Open UniversitySkip to content
 

Validation of the Contour Method of Residual Stress Measurement in a MIG 2024 Weld by Neutron and Synchrotron X-ray Diffraction

Zhang, Y.; Ganguly, S.; Stelmukh, V.; Fitzpatrick, M. E. and Edwards, L. (2003). Validation of the Contour Method of Residual Stress Measurement in a MIG 2024 Weld by Neutron and Synchrotron X-ray Diffraction. Journal of Neutron Research, 11(4) pp. 181–185.

DOI (Digital Object Identifier) Link: http://dx.doi.org/10.1080/10238160410001726594
Google Scholar: Look up in Google Scholar

Abstract

The contour method is a newly-invented destructive technique of residual stress measurement and has been receiving increasing interest. It is advisable to validate such new methods by comparison with other well-established techniques. For this purpose, contour measurements were performed on a MIG 2024-T351 aluminium alloy welded plate. The result has been compared with the results from neutron and synchrotron X-ray and shows a favourable agreement.

Item Type: Journal Article
ISSN: 1023-8166
Keywords: Residual stress; Weld; Contour method; Neutron; Synchrotron X-ray
Academic Unit/Department: Mathematics, Computing and Technology > Engineering & Innovation
Item ID: 11263
Depositing User: Michael E. Fitzpatrick
Date Deposited: 08 Aug 2008 08:43
Last Modified: 02 Dec 2010 20:09
URI: http://oro.open.ac.uk/id/eprint/11263
Share this page:

Altmetrics

Scopus Citations

Actions (login may be required)